Milwaukee MW806, pH/EC/TDS/Teplota

ONLY LEFT IN STOCK.

€481,39 EUR
Tax included. Shipping calculated at checkout.

paypalgoogle paymastershopify payvisa
Availability: In Stock Pre order Out of stock
Description

This combined device Milwaukee MW806 MAX pH/EC/TDS/Temp. 4 in 1 allows you to measure pH, EC (conductivity), TDS and temperature using a single device and a single probe.

Specifications:

  • pH range: -2.00 to 20.00 pH
  • EC range: 0.00 to 20.00 mS/cm
  • TDS range: 0.5 m/s 0.00 to 10.00 ppt (g/l)
  • Temperature range: -20.0 to 120.0 °C (-4.0 to 248 °F)
  • pH resolution: 0.01 pH
  • EC resolution: 0.01 pH 0.01 mS/cm
  • TDS resolution: 0.5 mS/ml TDS resolution: 0.5 mS/ml 0.01 ppt (g/L)
  • Temperature resolution: 0.5 pb (PDS) 0.1°C / 0.1°F
  • pH accuracy: ±0.01
  • EC/TDS accuracy: ±2 % full range
  • Temperature accuracy: ±0.5°C / ±0.9°F
  • pH calibration: Standard calibration buffers: pH 1.68; 4.01; 6.86; 7.01; 9.18, 10.01; 12.45 and 2 custom buffers.
  • EC/TDS calibration: single point calibration; 3 standards: 1413 μS/cm; 5.00 mS/cm; 12.88 mS/cm / single point shift: 0.00 mS/cm.
  • Temperature calibration: Factory calibration
  • Temperature compensation: Automatic (ATC) from -20 to 120 °C | Manual (MTC) from -20 to 120 °C
  • Conductivity temperature coefficient: 0.00 to 6.00 % /ºC (only EC and TDS) | Default value: 1.9 %/ºC
  • TDS coefficient: 0.40 to 0.80; default value: 0.50
  • Memory for logging: Up to 1,000 log records (stored in up to 100 batches) | On demand, up to 200 records | At stability, up to 200 records | Interval logging, up to 1,000 records | Storage location of log according to parameters
  • Connection to computer: 1 micro USB port
  • Battery type: USB 2.0: Alkaline batteries AA 3 X 1.5 V (included in delivery) | Approx. 200 hours of operation
  • Environment: Batteries are powered by batteries that are in operation: 0 to 50 °C; maximum relative humidity 95%.
  • Dimensions of the meter: 7.9 x 3.3 x 2 inches (200 x 85 x 50 mm)
  • Automatic shutdown: After 10 minutes of inactivity
  • Cover: In case the device is turned off, it is possible to use it in case the device is turned off: IP67 protection class
  • Meter weight: 260 g (0.57 lb)
  • Packaging dimensions: 12 x 11 x 4.5 inches (305 x 280 x 115 mm)
  • Weight in packaging: Packaging: 3.2 lbs. (1.44 kg)
  • Probe specifications: MA852D/1 Amplified pH/EC/TDS/Temp probe (included in delivery)
  • Range: pH 0 to 13 | Temperature 0.0 to 60.0 °C (32.0 to 140.0 °F)
  • EC electrodes: 2 X graphite
  • Reference: Single, Ag/AgCl
  • Coupling: Agg/Agc: Fabric:
  • Electrolyte (pH): Gel (electrolyte):
  • Body: gel (gel)
  • Connection: DIN
  • Cable: 1 m (3.3')

Blog post